• Users Online: 437
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2019  |  Volume : 8  |  Issue : 3  |  Page : 76-78

Safety and outcomes of noncardiac surgery in patients with cardiac implantable electronic devices


1 Department of Cardiac Electrophysiology; Cardiac Electrophysiology Research Center, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
2 Cardiovascular Diseases Research Center, Birjand University of Medical Sciences, Birjand, Iran

Correspondence Address:
Dr. Majid Haghjoo
Cardiac Electrophysiology Research Center, Rajaie Cardiovascular Medical and Research Center, Vali E Asr St., Ayatollah Rafsanjani Blvd, Tehran 1995614331
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/rcm.rcm_16_19

Get Permissions

Background: Electromagnetic interference can cause damage to cardiac implantable electronic devices (CIEDs). The current guidelines recommend the interrogation of all pacemakers and defibrillators before and after surgery. The objective of the study was to evaluate the safety and outcomes of noncardiac surgeries in patients with CIEDs. Methods: Between January 2014 and January 2019, all patients with CIEDs who underwent noncardiac surgery were included. The patient's baseline characteristics and data regarding their procedure and postsurgical complications and mortality were extracted from their medical records. The device analysis 6 months after the procedure was also seen. Results: Of the 54 patients, 16 had permanent pacemaker, 25 implantable cardioverter defibrillator, and 13 cardiac resynchronization therapy device. Most common indication for surgery was inguinal or abdominal hernia (n = 46); three patients underwent surgery for cholecystitis and five for other reasons. Supraventricular tachycardia was reported in one patient during surgery and in another one after surgery. Only one patient experienced intraoperative ventricular tachycardia. There was no device malfunction during and after surgery. During 6-month follow-up, 5.6% mortality rate was reported. Conclusions: With recommended device programming before surgery, noncardiac surgery is well tolerated in the majority of the patients with CIEDs without significant interference in the device function.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed18    
    Printed0    
    Emailed0    
    PDF Downloaded5    
    Comments [Add]    

Recommend this journal