RESEARCH ARTICLE
Year : 2014  |  Volume : 3  |  Issue : 4  |  Page : 6

LV dyssynchrony assessed with phase analysis on gated myocardial perfusion spect can predict response to crt in patients with end-stage heart failure


1 Cardiac Electrophysiology Research Center, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, IR Iran
2 Department of Nuclear Medicine and Molecular Imaging, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, IR Iran

Correspondence Address:
Majid Haghjoo
Cardiac Electrophysiology Research Center, Rajaie Cardiovascular Medical and Research Center, Vali-Asr St., Niayesh Blvd, Tehran
IR Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.5812/cardiovascmed.20720

Get Permissions

Background: Cardiac resynchronization therapy (CRT) is an established treatment in patients with end-stage heart failure and wide QRS complex. However, about 30% of patients do not benefit from CRT (non-responder). Recent studies with tissue Doppler imaging yielded disappointing results in predicting CRT responders. Phase analysis was developed to allow assessment of LV dyssynchrony by gated single photon emission computed tomography (SPECT) myocardial perfusion imaging (GMPS). Objectives: The aim of present study was to investigate the role of quantitative GMPS-derived LV dyssynchrony data to predict CRT responder. Patients and Methods: Thirty eligible patients for CRT implantation underwent GMPS and echocardiography. Response to CRT was evaluated six months after the device implantation. Clinical response to CRT was defined as 50 meters increase in 6-minute walking test (6-MWT) distance. Echocardiographic response to CRT was defined as ≥ 15% decrease in left ventricular end-systolic volume (LVESV). The lead position was considered concordant if it was positioned at the area of latest mechanical activation, and discordant if located outside the area of latest mechanical activation. Results: Clinical response to CRT was observed in 74% of patients. However, only 57% of patients were responder according to the echo criteria. There were statistically significant differences between CRT responders and non-responders for GMPS-derived variables, including phased histogram bandwidth (PHB), phase SD (PSD), and Entropy. Moreover, a cutoff value of 112° for PHB with a sensitivity of 72% and specificity of 70%, a cutoff value of 21° for PSD with a sensitivity of 90% and specificity of 74%, and a cutoff of 52% for Entropy with a sensitivity of 90% and a specificity of 80% were considered to discriminate responders and non-responders. CRT response was more likely in patients with concordant LV lead position compared to those with discordant LV lead position. Conclusions: GMPS-derived LV dyssynchrony variables can predict response to CRT with good sensitivity and specificity.


[PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed363    
    Printed30    
    Emailed0    
    PDF Downloaded47    
    Comments [Add]    
    Cited by others 8    

Recommend this journal